Bellini – 60/90cm gas hob
Rev: 8-9-2010 5
5. INSTALLATION
IMPORTANT NOTE: Refer to the Warnings in Section 1 of these Instructions.
This hotplate must be installed in accordance with:
AS 5601 - Gas Installations (for Australia)
NZS 5261 – Code of Practice for the Installation of Gas Burning Appliances
and Equipment (for New Zealand)
Local gas fitting regulations
AS/NZS 3000 – Electrical Installations (Wiring Rules)
Building codes
Any other relevant statutory regulations.
Check the gas type label on the underside of the hotplate, adjacent to the gas connection to
ensure it corresponds to the installation gas supply. If in doubt contact the supply authority.
NOTE: Before cutting into any bench tops, ensure the minimum clearances to walls, adjacent
surfaces and overhead surfaces required by the relevant gas appliance installation
code (see above) will comply. Dimensions are specified in millimetres (mm)
MINIMUM CLEARANCES:
Overhead cupboards and range hood = 600 mm.
Side and rear clearance = 200 mm to any burner edge.
Overhead exhaust/ceiling fan = 750 mm
Horizontal surfaces adjacent the hob = less than or equal to the hob height.
Ensure there is sufficient clearance to fit the regulator and/or flexible hose
connection with the hotplate in the installed position.
GAS and ELECTRICAL CONNECTION LOCATIONS and OVERALL DIMENSIONS:
Model CGH6401: Bench cutout size, 555 mm wide x 473 mm deep.
Bench top thickness, 30 – 40 mm (3 – 4 cm).